Calibrator

A water-cooled sizing block that holds a hot vinyl profile to shape while it sets.

The profile leaves the die soft. It passes through a series of calibrators that hold it to size with vacuum and cool it with water flowing through their metal. VEKA uses six to eight per profile, with the water chilled to 55 to 65 °F.

The inner chambers must be cooled as well as the outside. A profile that leaves the line still warm inside can warp or buckle as it finishes cooling.

A vinyl line in elevation, from salt and ethylene through the resin plant to profile extrusion

Hover or tap a part to see what it is called.

Vinyl line, from salt to profile, in elevation